HoldPeak HP-870CR Auto Range Digital Clamp Meter

Share

Tersedia
Auto Range Digital Clamp Meter -HP-870CR
Basic function
DC Voltage      400mV~1000V
 AC Voltage     400mV~750V
 DC Current      200A~1000A
 AC Current      400A~1000A
 Resistance      400Ω~40MΩ
 Capacitance    40nF~100uμF
 Temperature    -20℃~1000℃
 Frequency       10Hz~10MHz
 Duty Cycle       0.1%~99.9%
Express function
 Display                  3999
 Range Select         Auto
 Diode Test               √
 Continuity Buzzer    √
 Data Hold               √
 Back Light             √
 Auto Power Off      √
 Relative Value       √
 AC Ture RMS       √
  Dual Display       √
 Jaw Caliber        45mm
General Features
Battery Type       9V(6F22)x1
Dimension          230x85x40mm
Weight               450g
MOQ                 100
Ctn Size             530x310x400mm
Q'TY / Ctn          30
GW/NW            18/17

 

 

Function

Range

Accuracy

Resolution

Remarks

DCV

400mV

0.8% of rdg

0.1mV

Overload protection: 1000V DC/750Vrms AC

Impedance: 10MΩ,More than 100MΩ on 400mV scale

4V

1.0% of rdg

1mV

40V

10mV

400V

100mV

1000V

1.5% of rdg

1V

ACV

Range

Accuracy

Resolution

Frequency

Average sensing, calibrated to rms of sine wave

Overload protection: 1000V DC/750Vrms AC;Impedance: 10MΩ.

4V

1.5% of rdg

1mV

50~400Hz

40V

10mV

400V

100mV

750V

2.5% of rdg

1V

50~100Hz

DCA

Range

Accuracy

Resolution

Frequency

Overload protection: 1000Arms within 60 seconds

200A

3.0% of rdg

0.1A

-

1000A

0~800

3.5% of rdg

1A

 
 

800~1000

6.5% of rdg

ACA

Range

Accuracy

Resolution

Frequency

Average sensing, calibrated to rms of sine wave

Overload protection: 1000Arms within 60 seconds

400A

3.0% of rdg

0.1A

50~400Hz

1000A

0~800

3.5% of rdg

1A

800~1000

6.5% of rdg

ACV

(True RMS)

Range

Resolution

Accuracy

Sensitivity

1. Input impedance : > 10MΩ Ohm ACV True RMS.

2. Overload protect : 1000V DCV or ACV peak value.

3. Press “Range” button for select ACV 400mV range.

400mV

0.1mV

±2.0% of rdg

40Hz-1kHz

4V

1mV

±1.2% of rdg

40Hz-1kHz

40V

10mV

±1.2% of rdg

40Hz-10kHz

400V

100mV

±1.0% of rdg

40Hz-400Hz

750V

1V

±1.0% of rdg

40Hz-400Hz

Resistance

Range

Accuracy

Resolution

Overload protection: 250V DC/250Vrms AC

400Ω

1.5% of rdg+15 digits

0.1Ω

4kΩ

1.2% of rdg

40kΩ

10Ω

400kΩ

100Ω

4MΩ

1kΩ

40MΩ

2.5% of rdg

10kΩ

Capacitance

Range

Accuracy

Resolution

Overload protection: 250V DC/250Vrms AC

40nF

6.0% of rdg

10PF

400nF

3.5% of rdg

100PF

4μF

1nF

40μF

10nF

100μF

6.0% of rdg

100nF

Frequency

Range

Accuracy

Resolution

Sensitivity

Overload protection: 250V DC/250Vrms AC

10Hz

1.2% of rdg

0.01Hz

Range of input voltage:1.5V~10V, If input voltage over range, need adjust

100Hz

0.1Hz

1000Hz

0.8% of rdg

1Hz

10kHz

10Hz

100kHz

100Hz

1000kHz

1kHz

10MHz

2.0% of rdg

10kHz

Temperature(NiCr-NiSi sensor)

Range

Accuracy

Resolution

Overload protection: 36V DC/36Vrms AC

-20~150℃

3℃+2

1℃

150~300℃

3.0% of rdg

1℃

300~1000℃

3.5% of rdg

1℃

Diode and Audible continuity test

Range

Description

Test Condition

Overload protection: 250V DC/250Vrms AC

 

Display read approx.

Forward voltage of diode

Forward  DC current

approx. 0.4mA

Reversed DC voltage

approx. 1.5V

 

Built-in buzzer sounds

if resistance is  less

than 90Ω

Open circuit voltage

approx. 0.5V

                     

 

Nomor Produk

511

Tags

Clamp Meter, holdpeak, HP860C

Review