HoldPeak HP-870K Leakage Current Clamp Meters

Share

Tersedia
Leakage Current Clamp Meters -HP-870K
Basic function 

 DC Voltage     400mV~1000V
 AC Voltage     400mV~750V
 DC Current      400mA~30A
 AC Current      400mA~30A
 Resistance      400Ω~40MΩ
 Capacitance    40nF~100μF
 Temperature    -20℃~1000℃
 Frequency        5.12Hz~100kHz
 Duty Cycle       0.1%~99.9%

Express function

Display                           3999
Range Select                   Auto
AC Leaker Current Test      √
Auto Power Off                  √ 
Diode Test                        √
Continuity Buzzer              √ 
Data Hold                         √   
Back Light                        √
Relative Value                   √
Dual Display                     √
Jaw Caliber                     21mm

General Features

Battery Type      9V(6F22)x1
Dimension         230x85x40mm
Weight              450g
MOQ                30
Ctn Size           530x310x400mm
Q'TY / Ctn        30
GW/NW          18/17

 

Function

Range

Accuracy

Resolution

Remarks

DCA

400mV

1.2% of rdg

0.1mV

Overload protection: 1000V DC/750Vrms AC

Impedance: 10MΩ,More than 100MΩ on 400mV scale

4V

0.8% of rdg

1mV

40V

10mV

400V

100mV

1000V

1.5% of rdg

1V

DCV

Range

Accuracy

Resolution

Frequency

Average sensing, calibrated to rms of sine wave

Overload protection: 1000V DC/750Vrms AC

Impedance: 10MΩ.

400mV

±2.5% of rdg

0.1mV

50~100Hz

4V

1.2% of rdg

1mV

40V

10mV

400V

100mV

750V

2.5% of rdg

1V

ACV

Range

Accuracy

Resolution

Overload protection: 1000Arms within 60 seconds

4000mA

3.5% of rdg

1mA

30A

3.0% of rdg

10m A

ACA

Range

Accuracy

Resolution

Frequency

Average sensing, calibrated to rms of sine wave

Overload protection: 1000Arms within 60 seconds

4000mA

3.5% of rdg

1mA

50~60Hz

30A

3.0% of rdg

10m A

Resistance

Range

Accuracy

Resolution

Overload protection: 250V DC/250Vrms AC

400Ω

1.8% of rdg

0.1Ω

4kΩ

1.2% of rdg

40kΩ

10Ω

400kΩ

100Ω

4MΩ

1kΩ

40MΩ

2.0% of rdg

10kΩ

Capacitance

Range

Accuracy

Resolution

Overload protection: 250V DC/250Vrms AC

40nF

3.5% of rdg

10PF

400nF

2.5% of rdg

100PF

4μF

1nF

40μF

10nF

100μF

3.5% of rdg

100nF

Frequency

Range

Accuracy

Resolution

Sensitivity

Overload protection: 250V DC/250Vrms AC

Duty cycle:  0.1%99.9%

10Hz

0.5% of rdg

0.01Hz

Range of input voltage:1.5V~10V, If input voltage over range, need adjust

100Hz

0.1Hz

1000Hz

1Hz

10kHz

10Hz

Temperature(NiCr-NiSi sensor)

Range

Accuracy

Resolution

Overload protection: 250V DC/250Vrms AC

-20~150℃

3℃+2

<400℃

1℃

150~300℃

3.0% of rdg

<400℃

1℃

300~1000℃

3.5% of rdg

≥400℃

1℃

Diode and Audible continuity test

Range

Description

Test condition

Overload protection: 250V DC/250Vrms AC

 

Display read approx.

Forward voltage of diode.

Forward  DC current

approx. 0.4mA

Reversed DC voltage

approx. 1.5V

 

Built-in buzzer sounds

if resistance is  less

than 70Ω

Open circuit voltage

aprox. 0.5V

 

Nomor Produk

513

Tags

Clamp Meter, holdpeak, HP870k